Chapter 3 LPM Devices
©
National Instruments Corporation 3-3 DAQ Hardware Overview Guide
LPM Device Data Acquisition Rates
Table 3-1 shows the maximum recommended data acquisition rates.
LPM Device Digital I/O
The LPM devices contain one 8-bit digital input port and one 8-bit digital
output port. The digital I/O ports are labeled DIN and DOUT on the
I/O connector, as shown in your device user manual. The ports are referred
to as ports 0 and 1 for the Digital I/O functions, in which:
• DOUT = port 0
• DIN = port 1
You can program ports 0 and 1 for no-handshaking mode only. You can use
port 0 for no-handshaking digital output mode. You can use port 1 for
no-handshaking digital input mode.
LPM Device Interval Counter/Timer Operation
The LPM device interval counter/timer operation is the same as for the
Lab-PC+, except that the LPM devices have a single counter. Refer to the
Lab and 1200 Devices Interval Counter/Timer Operation section in
Chapter 2, Lab and 1200 Devices, for detailed information.
Table 3-1.
Maximum Recommended Data Acquisition Rates for the LPM Devices
Sample Mode
Maximum
Acquisition Rate
(kS/s)
Sample
Interval
(µs)
Single-channel scan 50 20
Multiple-channel scan
(0 to +5 V, −2.5 to +2.5 V,
and −5 to +5 V input ranges)
50 20
Multiple-channel scan
(0 to 10 V input range)
50 (typical)
45 (worst case)
20
22