E Series DAQ Devices
Measurements
Overview
The NI 6011E and NI 6012E DAQ
devices use E Series technology to
deliver reliable data acquisition
capabilities to meet a wide range of
application requirements. You get up to
20 kS/s, 16-bit performance on 16 analog
inputs. Depending on your hard drive,
these devices can also stream to disk
at rates up to 20 kS/s. The NI 601x
devices feature digital triggering
capability, as well as two 12-bit analog
outputs; two 24-bit, 20 MHz counter/
timers; and 8 digital I/O channels. All E Series devices include NI-DAQ
driver software.
For a detailed hardware overview, see the E Series Multifunction
DAQ Overview on page 230.
20 kS/s, 16-bit resolution,
16 analog inputs
Two 12-bit analog outputs
8 digital I/0 lines (5 V/TTL);
two 24-bit counter/timers
Digital triggering
Available for PCI, PCMCIA, and ISA
NI--DAQ driver software simplifies
configuration and measurements
Model
NI 6011E
• PCI-MIO-16XE-50
• AT-MIO-16XE-50
NI 6012E
• DAQCard-AI-16XE-50
NI Application Software
• LabVIEW
Measurement Studio
VI Logger
Operating System Compatibility
Windows 2000/NT/Me/9x*
Mac OS – not for all hardware
Accessories
See page 256
Calibration Certificate Included
See page 24
*Visit ni.com/info and enter winxp for the
latest operation system information.
NI 601xE
E Series Multifunction DAQ –
20 kS/s, 16-Bit, 16 Analog Inputs
INFO CODES
For more information
or to order products
online, visit ni.com/info
and enter:
pcimio16e1
pxi6070e
atmio16e1
daqpad6070e
pci6071e
pxi6071e
BUY ONLINE!
Analog Sampling Input Analog Output Output Digital Counter/
Family Bus Inputs Resolution Rate Range Outputs Resolution Rate Range I/O Timers Triggers
NI 6011E PCI, ISA, Parallel 16 SE/8 DI 16 bits 20 kS/s ±0.1 to ±10 V 2 12 bits 20 kS/s ±10 V 8 2, 24-bit Digital
NI 6012E PCMCIA 16 SE/8 DI 16 bits 20 kS/s ±0.1 to ±10 V 8 2, 24-bit Digital
Table 1. NI 601xE Channel, Speed, and Resolution Specifications (See page 271 for detailed specifications.)
Ordering Information
NI 6011E
PCI-MIO-16XE-50 ............................................777385-01
AT-MIO-16XE-50* ............................................776910-01
NI 6012E
DAQCard-AI-16XE-50........................................777231-01
Includes NI-DAQ driver software.
*Windows only
For information on extended warranty and value-added
services, see page 22.
Recommended Configurations
For E Series accessory and cable information, see page256.
Family DAQ Device Accessory Cable
NI 6011E PCI-MIO-16XE-50 SCB-68 (776844-01) SH6868-EP (184749-01)
AT-MIO-16XE-50 SCB-68 (776844-01) SH6868-EP (184749-01)
NI 6012E DAQCard-AI-16XE-50 SCB-68 (776844-01) PSHR68-68 (777293-01)
Vista de página 0
1 2 3 4 5 6 ... 19 20

Resumo do Conteúdo

Página 1 - E Series Multifunction DAQ –

254National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • [email protected] • ni.comE Series DAQ DevicesMeasurementsOverviewThe NI 6011E and NI

Página 2

Configurable Signal Conditioning EnclosureOverviewThe National Instruments CA-1000 is a configurable signal conditioningenclosure designed for maximum u

Página 3 - Selection Guide

Table 1. CA-1000 Cabling264National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • [email protected] • ni.comCustom Conditioning EnclosureMeasure

Página 4 - Connector Blocks

Configurable Signal Conditioning Enclosure265National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • [email protected] • ni.comCustom Conditioning

Página 5

AIGNDAIGNDACH0ACH8ACH1ACH9ACH2ACH10ACH3ACH11ACH4ACH12ACH5ACH13ACH6ACH14ACH7ACH15AISENSEDAC0OUT1DAC1OUT1EXTREF1AOGND1DGNDDIO0DIO4DIO1DIO5DIO2DIO6DIO3DI

Página 6 - Accessories and Cables

E Series Multifunction DAQ Specifications271National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • [email protected] • ni.comMeasurementsThese sp

Página 7

272National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • [email protected] • ni.com16-Bit E Series SpecificationsMeasurementsE Series Multifunct

Página 8

E Series Multifunction DAQ Specifications273National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • [email protected] • ni.com16-Bit E Series Spec

Página 9

274National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • [email protected] • ni.com16-Bit E Series SpecificationsMeasurementsE Series Multifunct

Página 10 - BUY ONLINE!

E Series Multifunction DAQ Specifications275National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • [email protected] • ni.com16-Bit E Series Spec

Página 11 - Interface Panelettes

234National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • [email protected] • ni.comE Series DAQ Accuracy Specifications MeasurementsEvery Measur

Página 12 - Ordering Information

E Series Multifunction DAQ –20 kS/s, 16-Bit, 16 Analog Inputs255National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • [email protected] • ni.co

Página 13

E Series DAQ Accuracy SpecificationsRelative AccuracyRelative accuracy is the specification that compares the differencebetween two or more measurements

Página 14 - 16-Bit E Series Specifications

256National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • [email protected] • ni.comE Series DAQ AccessoriesMeasurementsSelection GuideStep 1. S

Página 15

E Series Multifunction DAQ AccessoriesSCXI High-Performance Signal Conditioning (see Figure 1)SCXI is a modular high-performance signal conditioning p

Página 16

258National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • [email protected] • ni.comE Series DAQ AccessoriesMeasurementsCA-1000 Configurable Sign

Página 17

E Series Multifunction DAQ Accessories and CablesSignal Source and Demo Accessory (see Figure 10)The DAQ Signal Accessory demonstrates and tests the

Página 18

260National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • [email protected] • ni.comE Series DAQ Accessories and CablesMeasurementsSH1006868 Shi

Página 19 - Absolute Accuracy

E Series Multifunction DAQ Accessories and CablesRibbon I/O CablesR6868 Ribbon Cable for E Series Devices (see Figure 20)68-conductor flat ribbon cable

Página 20 - Detailed Specifications

262National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • [email protected] • ni.comE Series DAQ Accessories and CablesMeasurementsUSB Cable (se

Comentários a estes Manuais

Sem comentários